The EPOCH 6LT portable flaw detector combines the functionality of a powerful ultrasonic flaw detection device with a form factor designed to thrive in rope access and high portability applications. This flaw detector is a rugged instrument that delivers user comfort and more uptime. The unit weighs just 1.95 pounds (890 g) with a grip-oriented weight distribution for one-handed operation with minimal wrist fatigue, and rotary knob and simple button design make it easy to use, even when wearing gloves.

 

The EPOCH 6LT flaw detector’s workflow is simple and straightforward. Despite the instrument’s small size, it has the features and functions to meet the requirements of nearly any conventional ultrasonic inspection application.

 

Based on the same digital architecture as the EPOCH 650 flaw detector, the EPOCH 6LT flaw detector provides flexible, powerful pulsing and receiving features to accommodate the needs of most flaw detection inspections.

 

GENERAL

User Interface Languages

English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian, Italian

Transducer Connections LEMO 00

Data Storage 100,000 IDs onboard

Battery Type and Life Single lithium-ion rechargeable standard; 6 h life

Power Requirements AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 Hz to 60 Hz

Display Type Full VGA (640 × 480 pixels) transflective color LCD, 60 Hz update rate

Display Dimensions (W × H, Diag.) 117 mm × 89 mm, 146 mm (4.62 in. × 3.49 in., 5.76 in.)

Overall Dimensions (W × H × D) 209 mm x 128 mm x 36 mm, 58 mm at hand grip (8.2 in. x 5 in. x 1.4 in., 2.3 in. at hand grip)

Weight 890 g (1.95 lb), including lithium-ion battery

 

Instrument Inputs/Outputs

USB Ports (1) USB 1.1 Full Speed Host (Type A)

(1) USB 2.0 Full Speed Client (Type Mini B)

Video Output 1 digital video output

 

Environmental Ratings

IP Rating Ingress Protection (IP) engineered to IP67 (dust tight and water submersion) and IP65 (dust tight and water jets) per IEC 60529-2004 (Degrees of Protection provided by enclosures—IP Code). The product rating is confirmed by means of Olympus’ internal design verification test process.

Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure 1.

Shock Tested MIL-STD-810F, Method 516.5, Procedure I, 6 cycles each axis, 15 g, 11 ms half sine.

Vibration Tested MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis.

Operating Temperature -10 °C to 50 °C (14 °F to 122 °F)

Battery Storage Temperature 0 °C to 50 °C (32 °F to 122 °F)

 

Pulser

Pulser Turnable square wave

PRF 10 Hz to 2000 Hz in 10 Hz increments

Energy Settings 100 V, 200 V, 300 V, or 400 V

Pulse Width Adjustable from 25 nsec to 5,000 nsec (0.1 MHz) with PerfectSquare™ technology

Damping 50, 400 Ω

 

Receiver

Maximum Input Signal 20 Vp

Receiver Input Impedance 400 Ω ± 5%

Receiver Bandwidth DC to 26.5 MHz at -3 dB (standard version)

0.2 to 26.5 MHz at -3 dB (EN12668 compliant version)

Digital Filter Settings 8 digital filter sets (standard version)

7 digital filter sets (EN12668 compliant version)

Rectification Full-Wave, Positive Half-Wave, Negative Half-Wave, RF

System Linearity Horizontal: ± 0.5% FSW

Resolution 0.25% FSH, Amplifier Accuracy /- 1dB

Reject 0 to 85% FSH in 1% increment positions

Amplitude Measurement 1.25% to 110% full screen height

Measurement Rate Equivalent to PRF in all modes (single shot)

 

Calibration

Automated Calibration Velocity, zero offset

Straight beam (first back wall or echo-to-echo)

Angle beam (sound path or depth)

Test Modes Pulse Echo, Dual, or Through Transmission

Units Millimeters, inches, or microseconds

Range 4.31 mm to 6,700 mm at 5,900 m/s (0.2320 in./μs)

Velocity 635 m/s to 15240 m/s (0.0250 in./μs to 0.6000 in./μs)

Zero Offset 0 to 750 μs

Display Delay -10 microseconds to 2203 microseconds

Refracted Angle 0° to 85° in 0.1° increments, then jump to 90°

 

Gates

Measurement Gates 2 fully independent flaw gates

Gate Start Variable over entire displayed range

Gate Width Variable over entire displayed range

Gate Height Variable from 2 to 95% full screen height in 1% increments

Alarms Positive and negative threshold/curve, minimum depth (gate 1 and gate 2)

 

Measurements

Measurement Display Locations 5 locations available (manual or auto selection)

GATE (1, 2) Thickness, sound path, projection, depth, amplitude, time-of-flight, min./max. depth, min./max. amplitude, sizing measurements based on mode

Measurement Display Locations User selects up to four measurements from either gate to display on the live screen.

Echo-to-echo Standard gate 2 – gate 1

DAC/TCG Standard, up to 50 points, 110 dB dynamic TCG range

Special DAC Modes Custom DAC (up to 6 curves), 20–80% view

Curved Surface Correction Standard OD or bar correction for angle beam measurements.

 

 

The Following Items Are Included:

AC charger/adaptor

Lithium-ion rechargeable battery

USB Cable

User’s Manual (CD-Rom)

Basic Operation Manual

EPOCH 6LT Getting Started

Software

Transport case

Calibration Certificate