Loading...

Olympus Nortec 500D Eddy Current Flaw Detector (Used) - Sale!

Olympus

Very good condition & tested working!


$1,074.94


Qty:

Total Price:

  • Free Shipping

The Olympus Nortec 500 Series eddy current flaw detectors incorporate a full range of features: internal balance coils, VGA output connector (for heads up displays, monitors, and projectors), and a USB interface for rapid information transfer. The Olympus Nortec 500 also includes PowerLink, for automatic probe recognition and program set-up.

 

The Nortec 500 improves on previous Nortec eddy current instruments and is available in four configurations. Each configuration includes a USB port and increased resolution with reduced noise. Internal balance coils allow use of inexpensive absolute probes without the need or external balance coil adapters. A builtin preamp adds extra gain when needed for difficult tests. VGA output allows for the display to be projected or viewed on a standard computer screen. The optional remote-null adapter adds convenience by allowing the probe to be nulled and the instrument screen erased from the probe.

 

Where weight is critical, the smaller battery lightens the instrument to 1.2 kg (2.8 lbs) while keeping the full VGA resolution and display size.

 

Features:

50 Hz to 12 MHz frequency range

Preamplifier (0 or 14 dB)

Single Li-Ion battery, choice of two battery configurations: 2.4 Ahr or 8.8 Ahr

Lightweight, 1.2 kg to 1.7 kg (2.8 lbs to 3.8 lbs) depending on battery configuration

165 mm (6.5 in.) full VGA color LCD (640 x 480 resolution)

On-board storage of up to 200 programs

On-screen reference memory for go/no go applications

Internal balance loads for single coil probe support

Display Freeze to hold flaw signals

PowerLink technology – automatic probe recognition and instrument set-up

Foreign Object Debris (FOD) free case design

VGA output

 

GENERAL

Dimensions: (W x H x D)216 mm x 140 mm x 61 mm (8.5 in. x 5.5 in. x 2.4 in

Weight: 1.2 kg to 1.7 kg (2.8 lbs to 3.8 lbs), depending upon configuration

Display: 133 mm x 99 mm, 165 mm diagonal (5.25 in. x 3.9 in., 6.5 in.) full VGA color LCD (640 x 480 pixels)

Operating temperature: –10 ºC to 55 ºC (14 ºF to 122 ºF)

Humidity: 5% to 95%

Classification: Based on Class 2 specifications from the MIL-PRF-28800F handbook

Altitude: Maximum operating and non-operating altitude – 4600 m (15,000 ft)

Hazardous area operation: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1

Probe types: Absolute and differential in either bridge or reflection configuration. The instrument is fully compatible with Nortec PowerLink probes.

Alarms: Can be set to trigger on positive or negative box, polar, or sweep alarm settings

Alarm modes: 1 to 3 box gates, polar, sweep, conductivity, and coating thickness

Trace storage: Up to 200 traces can be stored for recall. The traces can be static or frozen and can contain up to 60 seconds of movement. The traces are stored with the date and time of capture.

Program storage: Up to 200 instrument set-ups may be stored and recalled. The date and time of storage is recorded with each set-up.

Print out: Provides a custom configurable report header containing the display screen data and probe parameters including serial numbers (PowerLink probes only)

 

MEASUREMENT

Frequency range: 50 Hz to 12 MHz

Gain: 0 dB to 90 dB in 0.1 dB steps. The horizontal and vertical gains may be adjusted separately or together.

Rotation: Variable 0º to 359º in 1º steps

Sweep: Variable from 0.005 s to 4 s per division

Low Pass filter

10 Hz to 500 Hz and wide band

High Pass filter: Off or 2.0 Hz to 500 Hz, 2 pole response

Built-in preamplifier: 5X (14 dB) additional gain.

Probe drive: 2 volts, 6 volts, 12 volts

Variable persistence: 0.1 s to 5 s

 

INPUTS/OUTPUTS

Power: 2-pin connector to charge the internal batteries and operate the instrument from AC power

USB port: Allows interface with PC and printers

Probe connector: 16-pin LEMO and BNC

Analog outputs: Horizontal and vertical outputs of both F1 and F2. /– 5 V, 1 V per division (four outputs)

Alarm outputs: 15-pin analog and alarm output connector

VGA output: 15-pin connector

 

POWER

Power requirements: 85 V to 240 V, 50 Hz to 60 Hz. Battery can be

charged within the instrument or in an external charger. Charge typically takes 4 hours.

Available batteries: 2.4 Ahr Li-ion or 8.8 Ahr Li-ion

Low battery protection: Display bar graph “gas gauge” indicates approximate operating time. A low battery annunciator indicates when approximately 10 minutes of operation time is left.

Battery operating time: 3 to 8 hours nominal depending on configuration and scanner usage

 

Configurations of the Olympus Nortec 500:

The Olympus Nortec 500 delivers basic single frequency eddy current inspection including external outputs.

The Olympus Nortec 500C adds digital conductivity and coating thickness measurement capability in addition to basic single frequency eddy current inspection.

The Olympus Nortec 500S builds on the foundation of the N500C and adds the ability to use rotating scanners.

The Olympus Nortec 500D adds dual frequency capabilities to all the functions of the N500S.

 

Includes:

N500D Instrument

Operation manual

Cable box(2 USB cables

CL/SC/6)

Power supply/charger

Instrument carry case

Eddy master software CD

Power Cord

Certificate of calibration

  • Availability: In Stock
  • Model: Nortec 500D
  • Brand: Olympus

Reviews

There are no reviews for this product.

Write a Review

*
*
Note: Do not use HTML in the text.
*
captcha
*